12 August 2025
- Corrected TE buffer formulation to (10 mM Tris-HCl, 1 mM EDTA, pH 8.0) in the "Size selection of gDNA using SFE Buffer" section of the protocol. Previously said 0.1 mM EDTA.
5/19/2025
HVB_9206_v114_revH_22Jan2025
English
PromethION
22 January 2025
- Document title change
- Extraction: Minor adjustments made to mitigate steps where errors may occur.
- Size selection using SFE: Updated method in-line with latest recommendations.
- Megaruptor shearing: Added more context for handling the device effectively.
- Flow cell wash and reload: updated data images and included image for sequencing read length profile.
1/22/2025
HVB_9206_v114_revH_22Jan2025
English
PromethION
22 January 2025
- Document title change
- Extraction: Minor adjustments made to mitigate steps where errors may occur.
- Size selection using SFE: Updated method in-line with latest recommendations.
- Megaruptor shearing: Added more context for handling the device effectively.
- Flow cell wash and reload: updated data images and included image for sequencing read length profile.
9/30/2024
HVB_9206_v114_revG_14May2024
English
PromethION
21st August 2024
- NEBNext® Companion Module v2 for Oxford Nanopore Technologies® Ligation Sequencing (NEB, E7672S or E7672L) is now the recommended reagent module.
- Updated the Repair and End-prep method in-line with new recommended reagents.
- Updated the Adapter ligation step with new recommended method.
- Data acquisition and basecalling instructions updated.
8/21/2024
HVB_9206_v114_revG_14May2024
English
PromethION
21st August 2024
- NEBNext® Companion Module v2 for Oxford Nanopore Technologies® Ligation Sequencing (NEB, E7672S or E7672L) is now the recommended reagent module.
- Updated the Repair and End-prep method in-line with new recommended reagents.
- Updated the Adapter ligation step with new recommended method.
- Data acquisition and basecalling instructions updated.
31 July 2024
- Changed reagent order addition in Library preparation/Adapter ligation and clean-up; Ligation Adapter (LA) added before Ligation Buffer (LB) and NEBNext Quick T4 Ligase
26 June 2024
- Swapped the use of Short Fragment Buffer (SFB) to Long Fragment Buffer (LFB) in the "Adapter ligation and clean-up" step of the protocol.
26 June 2024
- Swapped the use of Short Fragment Buffer (SFB) to Long Fragment Buffer (LFB) in the "Adapter ligation and clean-up" step of the protocol.
ONT plc is a member of the producer compliance scheme run by ERP UK Ltd, who manage the submission of documentation in support of WEEE compliance for ONT plc’s manufacture and supply of Electrical and Electronic equipment in the UK.