From portable to high-throughput benchtop devices, real-time nanopore sensing is a new generation of technology uncovering new biology across multiple sectors.
23st August 2024
- Reverted the Sample preparation section to Human cell line DNA extraction using the QIAGEN Puregene Cell Kit & Shearing DNA for 10 kb input using the Covaris g-TUBE™
- Sample input recommendation into library preparation reverted to 1 ug.
21st August 2024
- Updated workflow overview image.
- Updated sample preparation instructions.
- Updated sample input recommendation into library preparation.
- NEBNext® Companion Module v2 for Oxford Nanopore Technologies® Ligation Sequencing (NEB, E7672S or E7672L) is now the recommended reagent module.
- Updated the Repair and End-prep method in-line with new recommended reagents.
- Updated the Adapter ligation step with new recommended method.
- Data acquisition and basecalling instructions updated.
- Downstream analysis section updated.
23st August 2024
- Reverted the Sample preparation section to Human cell line DNA extraction using the QIAGEN Puregene Cell Kit & Shearing DNA for 10 kb input using the Covaris g-TUBE™
- Sample input recommendation into library preparation reverted to 1 ug.
21st August 2024
- Updated workflow overview image.
- Updated sample preparation instructions.
- Updated sample input recommendation into library preparation.
- NEBNext® Companion Module v2 for Oxford Nanopore Technologies® Ligation Sequencing (NEB, E7672S or E7672L) is now the recommended reagent module.
- Updated the Repair and End-prep method in-line with new recommended reagents.
- Updated the Adapter ligation step with new recommended method.
- Data acquisition and basecalling instructions updated.
- Downstream analysis section updated.
21st August 2024
- Updated workflow overview image.
- Updated sample preparation instructions.
- Updated sample input recommendation into library preparation.
- NEBNext® Companion Module v2 for Oxford Nanopore Technologies® Ligation Sequencing (NEB, E7672S or E7672L) is now the recommended reagent module.
- Updated the Repair and End-prep method in-line with new recommended reagents.
- Updated the Adapter ligation step with new recommended method.
- Data acquisition and basecalling instructions updated.
- Downstream analysis section updated.
31 July 2024
- Changed reagent order addition in Library preparation/Adapter ligation and clean-up; Ligation Adapter (LA) added before Ligation Buffer (LB) and NEBNext Quick T4 Ligase
30 April 2024
- Updated 'Downstream analysis' instructions.
1st August 2023
- Kit contents layout has been updated
- In priming and loading the flow cell, the flow cell priming mix instructions have been updated
10th July 2023
- Updated "Data acquisition and basecalling" to use the most recent MinKNOW GUI version in screenshots
- Updated "Downstream analysis" with the most recent recommendations from EPI2ME labs to ensure successful sequencing and data analysis
- Updated recommendation in the "Downstream analysis" to use modkit not modbam2bed has been depricated.
10th July 2023
- Updated "Data acquisition and basecalling" to use the most recent MinKNOW GUI version in screenshots
- Updated "Downstream analysis" with the most recent recommendations from EPI2ME labs to ensure successful sequencing and data analysis