Products

Discover nanopore sequencing

What can it do? How does it work? Our platform performance and accuracy

Explore products

Prepare Sequence Analyse
Store Resources Support About
Back

BulkVis: a graphical viewer for Oxford nanopore bulk FAST5 files

Tool

Date: 20th November 2018 | Source:

Authors: Alexander Payne, Nadine Holmes, Vardhman Rakyan, Matthew Loose

Motivation
The Oxford Nanopore Technologies (ONT) MinION is used for sequencing a wide variety of sample types with diverse methods of sample extraction. Nanopore sequencers output FAST5 files containing signal data subsequently base called to FASTQ format. Optionally, ONT devices can collect data from all sequencing channels simultaneously in a bulk FAST5 file enabling inspection of signal in any channel at any point. We sought to visualize this signal to inspect challenging or difficult to sequence samples.

Results
The BulkVis tool can load a bulk FAST5 file and overlays MinKNOW (the software that controls ONT sequencers) classifications on the signal trace and can show mappings to a reference. Users can navigate to a channel and time or, given a FASTQ header from a read, jump to its specific position. BulkVis can export regions as Nanopore base caller compatible reads. Using BulkVis, we find long reads can be incorrectly divided by MinKNOW resulting in single DNA molecules being split into two or more reads. The longest seen to date is 2,272,580 bases in length and reported in eleven consecutive reads. We provide helper scripts that identify and reconstruct split reads given a sequencing summary file and alignment to a reference. We note that incorrect read splitting appears to vary according to input sample type and is more common in ’ultra-long’ read preparations.

Availability and implementation
The software is available freely under an MIT license at https://github.com/LooseLab/bulkvis.

Bioinformatics - Full text

Recommended for you