From portable to high-throughput benchtop devices, real-time nanopore sensing is a new generation of technology uncovering new biology across multiple sectors.
21st August 2024
- Updated protocol introduction to new format.
- Updated sample input recommendations to 100 ng for gDNA or amplicons.
- NEB reagent recommendations for purchase and use updated.
- Updated the End-prep method in-line with new recommended reagents.
- Updated the Adapter ligation step with new recommended method.
- Updated library loading on flow cell recommendations with table for different DNA size.
Aug 21 2024
LWP_9183_v114_revK_07Mar2023
English
MinION
21st August 2024
- Updated protocol introduction to new format.
- Updated sample input recommendations to 100 ng for gDNA or amplicons.
- NEB reagent recommendations for purchase and use updated.
- Updated the End-prep method in-line with new recommended reagents.
- Updated the Adapter ligation step with new recommended method.
- Updated library loading on flow cell recommendations with table for different DNA size.
Aug 21 2024
LWP_9183_v114_revK_07Mar2023
English
PromethION
21st August 2024
- Updated protocol introduction to new format.
- Updated sample input recommendations to 100 ng for gDNA or amplicons.
- NEB reagent recommendations for purchase and use updated.
- Updated the End-prep method in-line with new recommended reagents.
- Updated the Adapter ligation step with new recommended method.
- Updated library loading on flow cell recommendations with table for different DNA size.
31 July 2024
- Changed reagent order addition in Library preparation/Adapter ligation and clean-up; Ligation Adapter (LA) added before Ligation Buffer (LB) and NEBNext Quick T4 Ligase
07th March 2024
- Updated library loading recommendations to 35-50 fmols.
31 July 2024
- Changed reagent order addition in Library preparation/Adapter ligation and clean-up; Ligation Adapter (LA) added before Ligation Buffer (LB) and NEBNext Quick T4 Ligase
07th March 2024
- Updated library loading recommendations to 35-50 fmols.
31 July 2024
- Changed reagent order addition in Library preparation/Adapter ligation and clean-up; Ligation Adapter (LA) added before Ligation Buffer (LB) and NEBNext Quick T4 Ligase
07th March 2024
- Updated library loading recommendations to 35-50 fmols.
19th September 2023
- Updated flow cell loading instructions to include light shield installation
- Updated flow cell loading recommendations in the "Adapter ligation and clean-up" step.
19th September 2023
- Updated flow cell loading instructions to include light shield installation
- Updated flow cell loading recommendations in the "Adapter ligation and clean-up" step.
19th September 2023
- Updated flow cell loading instructions to include light shield installation
- Updated flow cell loading recommendations in the "Adapter ligation and clean-up" step.
1st August 2023
- Kit contents layout has been updated
- In priming and loading the flow cell, the flow cell priming mix instructions have been updated
1st August 2023
- Kit contents layout has been updated
- In priming and loading the flow cell, the flow cell priming mix instructions have been updated
1st August 2023
- Kit contents layout has been updated
- In priming and loading the flow cell, the flow cell priming mix instructions have been updated