From portable to high-throughput benchtop devices, real-time nanopore sensing is a new generation of technology uncovering new biology across multiple sectors.
2nd April 2025
- Early access was removed from protocol.
- In 'Steps in the sequencing workflow', under 'Library preparation', timings in the Figure were edited to align with the Table.
- In 'Direct RNA Sequencing Kit (SQK-RNA004) contents', the RNA CS (RCS) described previously as the 'calibration' strand was changed to 'control' strand in the note under the Table.
- Consumables and equipment available from Oxford Nanopore were included in Section 2, 'Equipment and consumables'.
- Hyperlink for DNA/RNA handling was updated in 'Input RNA'.
- Addition of a Checkpoint to 'Perform a flow cell check' in Section 3, 'Library Preparation' and in Step 1, to ensure that the T4 DNA Ligase is kept on ice and not thawed.
- Steps 9, 12, and 37 were edited for clarity.
- For flow cell image 1a in 'Priming and loading the MinION/GridION Flow Cell', the word 'DNA' was removed from library.
- For the PromethION branch, the Step for removing PromethION Flow Cell out of the fridge was moved to the beginning of the Section on 'Priming and loading the PromethION Flow Cell' to enable the flow cell to reach room temperature while the flow cell priming mix is prepared. And an optional action of performing a flow cell check was included.
- In Section 5, 'Data acquisition and basecalling', 'To start a sequencing run in MinKNOW', the specific RNA kit was specified in point 3, 'Select the Direct RNA Sequencing Kit (SQK-RNA004) on the Kit selection page'.
- The function of the Flow Cell Wash Kit in Section 6, 'Flow cell reuse and returns' was edited for clarity.
4/2/2025
DRS_9195_v4_revG_02Apr2025
English
MinION
2nd April 2025
- Early access was removed from protocol.
- In 'Steps in the sequencing workflow', under 'Library preparation', timings in the Figure were edited to align with the Table.
- In 'Direct RNA Sequencing Kit (SQK-RNA004) contents', the RNA CS (RCS) described previously as the 'calibration' strand was changed to 'control' strand in the note under the Table.
- Consumables and equipment available from Oxford Nanopore were included in Section 2, 'Equipment and consumables'.
- Hyperlink for DNA/RNA handling was updated in 'Input RNA'.
- Addition of a Checkpoint to 'Perform a flow cell check' in Section 3, 'Library Preparation' and in Step 1, to ensure that the T4 DNA Ligase is kept on ice and not thawed.
- Steps 9, 12, and 37 were edited for clarity.
- For flow cell image 1a in 'Priming and loading the MinION/GridION Flow Cell', the word 'DNA' was removed from library.
- For the PromethION branch, the Step for removing PromethION Flow Cell out of the fridge was moved to the beginning of the Section on 'Priming and loading the PromethION Flow Cell' to enable the flow cell to reach room temperature while the flow cell priming mix is prepared. And an optional action of performing a flow cell check was included.
- In Section 5, 'Data acquisition and basecalling', 'To start a sequencing run in MinKNOW', the specific RNA kit was specified in point 3, 'Select the Direct RNA Sequencing Kit (SQK-RNA004) on the Kit selection page'.
- The function of the Flow Cell Wash Kit in Section 6, 'Flow cell reuse and returns' was edited for clarity.
4/2/2025
DRS_9195_v4_revG_02Apr2025
English
PromethION
2nd April 2025
- Early access was removed from protocol.
- In 'Steps in the sequencing workflow', under 'Library preparation', timings in the Figure were edited to align with the Table.
- In 'Direct RNA Sequencing Kit (SQK-RNA004) contents', the RNA CS (RCS) described previously as the 'calibration' strand was changed to 'control' strand in the note under the Table.
- Consumables and equipment available from Oxford Nanopore were included in Section 2, 'Equipment and consumables'.
- Hyperlink for DNA/RNA handling was updated in 'Input RNA'.
- Addition of a Checkpoint to 'Perform a flow cell check' in Section 3, 'Library Preparation' and in Step 1, to ensure that the T4 DNA Ligase is kept on ice and not thawed.
- Steps 9, 12, and 37 were edited for clarity.
- For flow cell image 1a in 'Priming and loading the MinION/GridION Flow Cell', the word 'DNA' was removed from library.
- For the PromethION branch, the Step for removing PromethION Flow Cell out of the fridge was moved to the beginning of the Section on 'Priming and loading the PromethION Flow Cell' to enable the flow cell to reach room temperature while the flow cell priming mix is prepared. And an optional action of performing a flow cell check was included.
- In Section 5, 'Data acquisition and basecalling', 'To start a sequencing run in MinKNOW', the specific RNA kit was specified in point 3, 'Select the Direct RNA Sequencing Kit (SQK-RNA004) on the Kit selection page'.
- The function of the Flow Cell Wash Kit in Section 6, 'Flow cell reuse and returns' was edited for clarity.
4/2/2025
DRS_9195_v4_revG_02Apr2025
Español
MinION
2nd April 2025
- Early access was removed from protocol.
- In 'Steps in the sequencing workflow', under 'Library preparation', timings in the Figure were edited to align with the Table.
- In 'Direct RNA Sequencing Kit (SQK-RNA004) contents', the RNA CS (RCS) described previously as the 'calibration' strand was changed to 'control' strand in the note under the Table.
- Consumables and equipment available from Oxford Nanopore were included in Section 2, 'Equipment and consumables'.
- Hyperlink for DNA/RNA handling was updated in 'Input RNA'.
- Addition of a Checkpoint to 'Perform a flow cell check' in Section 3, 'Library Preparation' and in Step 1, to ensure that the T4 DNA Ligase is kept on ice and not thawed.
- Steps 9, 12, and 37 were edited for clarity.
- For flow cell image 1a in 'Priming and loading the MinION/GridION Flow Cell', the word 'DNA' was removed from library.
- For the PromethION branch, the Step for removing PromethION Flow Cell out of the fridge was moved to the beginning of the Section on 'Priming and loading the PromethION Flow Cell' to enable the flow cell to reach room temperature while the flow cell priming mix is prepared. And an optional action of performing a flow cell check was included.
- In Section 5, 'Data acquisition and basecalling', 'To start a sequencing run in MinKNOW', the specific RNA kit was specified in point 3, 'Select the Direct RNA Sequencing Kit (SQK-RNA004) on the Kit selection page'.
- The function of the Flow Cell Wash Kit in Section 6, 'Flow cell reuse and returns' was edited for clarity.
4/2/2025
DRS_9195_v4_revG_02Apr2025
中文
MinION
2nd April 2025
- Early access was removed from protocol.
- In 'Steps in the sequencing workflow', under 'Library preparation', timings in the Figure were edited to align with the Table.
- In 'Direct RNA Sequencing Kit (SQK-RNA004) contents', the RNA CS (RCS) described previously as the 'calibration' strand was changed to 'control' strand in the note under the Table.
- Consumables and equipment available from Oxford Nanopore were included in Section 2, 'Equipment and consumables'.
- Hyperlink for DNA/RNA handling was updated in 'Input RNA'.
- Addition of a Checkpoint to 'Perform a flow cell check' in Section 3, 'Library Preparation' and in Step 1, to ensure that the T4 DNA Ligase is kept on ice and not thawed.
- Steps 9, 12, and 37 were edited for clarity.
- For flow cell image 1a in 'Priming and loading the MinION/GridION Flow Cell', the word 'DNA' was removed from library.
- For the PromethION branch, the Step for removing PromethION Flow Cell out of the fridge was moved to the beginning of the Section on 'Priming and loading the PromethION Flow Cell' to enable the flow cell to reach room temperature while the flow cell priming mix is prepared. And an optional action of performing a flow cell check was included.
- In Section 5, 'Data acquisition and basecalling', 'To start a sequencing run in MinKNOW', the specific RNA kit was specified in point 3, 'Select the Direct RNA Sequencing Kit (SQK-RNA004) on the Kit selection page'.
- The function of the Flow Cell Wash Kit in Section 6, 'Flow cell reuse and returns' was edited for clarity.
4/2/2025
DRS_9195_v4_revG_02Apr2025
中文
PromethION
2nd April 2025
- Early access was removed from protocol.
- In 'Steps in the sequencing workflow', under 'Library preparation', timings in the Figure were edited to align with the Table.
- In 'Direct RNA Sequencing Kit (SQK-RNA004) contents', the RNA CS (RCS) described previously as the 'calibration' strand was changed to 'control' strand in the note under the Table.
- Consumables and equipment available from Oxford Nanopore were included in Section 2, 'Equipment and consumables'.
- Hyperlink for DNA/RNA handling was updated in 'Input RNA'.
- Addition of a Checkpoint to 'Perform a flow cell check' in Section 3, 'Library Preparation' and in Step 1, to ensure that the T4 DNA Ligase is kept on ice and not thawed.
- Steps 9, 12, and 37 were edited for clarity.
- For flow cell image 1a in 'Priming and loading the MinION/GridION Flow Cell', the word 'DNA' was removed from library.
- For the PromethION branch, the Step for removing PromethION Flow Cell out of the fridge was moved to the beginning of the Section on 'Priming and loading the PromethION Flow Cell' to enable the flow cell to reach room temperature while the flow cell priming mix is prepared. And an optional action of performing a flow cell check was included.
- In Section 5, 'Data acquisition and basecalling', 'To start a sequencing run in MinKNOW', the specific RNA kit was specified in point 3, 'Select the Direct RNA Sequencing Kit (SQK-RNA004) on the Kit selection page'.
- The function of the Flow Cell Wash Kit in Section 6, 'Flow cell reuse and returns' was edited for clarity.
1/30/2025
DRS_9195_v4_revF_11Dec2024
English
GridION
11th Dec 2024
- Updated kit content to include information on different RNA CS (RCS) vial concentration in new kit batches.
- Updated instructions to include options for lower RNA CS (RCS) concentration (old) and higher RNA CS (RCS) concentraction (new).
- Addition of links to MinION Mk1D IT requirements in "Compatibility of this protocol" and user manual in "Data acquisition and basecalling", "How to start sequencing".
- Arrow which was previously at the bottom edge of the flow cell in Image 1b "Priming and loading MinION/GridION Flow Cell" was moved to the middle of the flow cell.
- Updated link for flow cell returns in "Flow cell reuse and returns" and removed note for flushing flow cells.
- Updated link for EPI2ME in "Downstream analysis".
- Updated link for MinION temperature control in "Issues during a sequencing run", "Failed to reach target temperature".
1/30/2025
DRS_9195_v4_revF_11Dec2024
English
MinION
11th Dec 2024
- Updated kit content to include information on different RNA CS (RCS) vial concentration in new kit batches.
- Updated instructions to include options for lower RNA CS (RCS) concentration (old) and higher RNA CS (RCS) concentraction (new).
- Addition of links to MinION Mk1D IT requirements in "Compatibility of this protocol" and user manual in "Data acquisition and basecalling", "How to start sequencing".
- Arrow which was previously at the bottom edge of the flow cell in Image 1b "Priming and loading MinION/GridION Flow Cell" was moved to the middle of the flow cell.
- Updated link for flow cell returns in "Flow cell reuse and returns" and removed note for flushing flow cells.
- Updated link for EPI2ME in "Downstream analysis".
- Updated link for MinION temperature control in "Issues during a sequencing run", "Failed to reach target temperature".
1/30/2025
DRS_9195_v4_revF_11Dec2024
English
PromethION
11th Dec 2024
- Updated kit content to include information on different RNA CS (RCS) vial concentration in new kit batches.
- Updated instructions to include options for lower RNA CS (RCS) concentration (old) and higher RNA CS (RCS) concentraction (new).
- Addition of links to MinION Mk1D IT requirements in "Compatibility of this protocol" and user manual in "Data acquisition and basecalling", "How to start sequencing".
- Arrow which was previously at the bottom edge of the flow cell in Image 1b "Priming and loading MinION/GridION Flow Cell" was moved to the middle of the flow cell.
- Updated link for flow cell returns in "Flow cell reuse and returns" and removed note for flushing flow cells.
- Updated link for EPI2ME in "Downstream analysis".
- Updated link for MinION temperature control in "Issues during a sequencing run", "Failed to reach target temperature".
1/30/2025
DRS_9195_v4_revF_11Dec2024
Español
GridION
11th Dec 2024
- Updated kit content to include information on different RNA CS (RCS) vial concentration in new kit batches.
- Updated instructions to include options for lower RNA CS (RCS) concentration (old) and higher RNA CS (RCS) concentraction (new).
- Addition of links to MinION Mk1D IT requirements in "Compatibility of this protocol" and user manual in "Data acquisition and basecalling", "How to start sequencing".
- Arrow which was previously at the bottom edge of the flow cell in Image 1b "Priming and loading MinION/GridION Flow Cell" was moved to the middle of the flow cell.
- Updated link for flow cell returns in "Flow cell reuse and returns" and removed note for flushing flow cells.
- Updated link for EPI2ME in "Downstream analysis".
- Updated link for MinION temperature control in "Issues during a sequencing run", "Failed to reach target temperature".
1/30/2025
DRS_9195_v4_revF_11Dec2024
Español
MinION
11th Dec 2024
- Updated kit content to include information on different RNA CS (RCS) vial concentration in new kit batches.
- Updated instructions to include options for lower RNA CS (RCS) concentration (old) and higher RNA CS (RCS) concentraction (new).
- Addition of links to MinION Mk1D IT requirements in "Compatibility of this protocol" and user manual in "Data acquisition and basecalling", "How to start sequencing".
- Arrow which was previously at the bottom edge of the flow cell in Image 1b "Priming and loading MinION/GridION Flow Cell" was moved to the middle of the flow cell.
- Updated link for flow cell returns in "Flow cell reuse and returns" and removed note for flushing flow cells.
- Updated link for EPI2ME in "Downstream analysis".
- Updated link for MinION temperature control in "Issues during a sequencing run", "Failed to reach target temperature".
1/30/2025
DRS_9195_v4_revF_11Dec2024
Español
PromethION
11th Dec 2024
- Updated kit content to include information on different RNA CS (RCS) vial concentration in new kit batches.
- Updated instructions to include options for lower RNA CS (RCS) concentration (old) and higher RNA CS (RCS) concentraction (new).
- Addition of links to MinION Mk1D IT requirements in "Compatibility of this protocol" and user manual in "Data acquisition and basecalling", "How to start sequencing".
- Arrow which was previously at the bottom edge of the flow cell in Image 1b "Priming and loading MinION/GridION Flow Cell" was moved to the middle of the flow cell.
- Updated link for flow cell returns in "Flow cell reuse and returns" and removed note for flushing flow cells.
- Updated link for EPI2ME in "Downstream analysis".
- Updated link for MinION temperature control in "Issues during a sequencing run", "Failed to reach target temperature".
1/30/2025
DRS_9195_v4_revF_11Dec2024
中文
GridION
11th Dec 2024
- Updated kit content to include information on different RNA CS (RCS) vial concentration in new kit batches.
- Updated instructions to include options for lower RNA CS (RCS) concentration (old) and higher RNA CS (RCS) concentraction (new).
- Addition of links to MinION Mk1D IT requirements in "Compatibility of this protocol" and user manual in "Data acquisition and basecalling", "How to start sequencing".
- Arrow which was previously at the bottom edge of the flow cell in Image 1b "Priming and loading MinION/GridION Flow Cell" was moved to the middle of the flow cell.
- Updated link for flow cell returns in "Flow cell reuse and returns" and removed note for flushing flow cells.
- Updated link for EPI2ME in "Downstream analysis".
- Updated link for MinION temperature control in "Issues during a sequencing run", "Failed to reach target temperature".
1/30/2025
DRS_9195_v4_revF_11Dec2024
中文
MinION
11th Dec 2024
- Updated kit content to include information on different RNA CS (RCS) vial concentration in new kit batches.
- Updated instructions to include options for lower RNA CS (RCS) concentration (old) and higher RNA CS (RCS) concentraction (new).
- Addition of links to MinION Mk1D IT requirements in "Compatibility of this protocol" and user manual in "Data acquisition and basecalling", "How to start sequencing".
- Arrow which was previously at the bottom edge of the flow cell in Image 1b "Priming and loading MinION/GridION Flow Cell" was moved to the middle of the flow cell.
- Updated link for flow cell returns in "Flow cell reuse and returns" and removed note for flushing flow cells.
- Updated link for EPI2ME in "Downstream analysis".
- Updated link for MinION temperature control in "Issues during a sequencing run", "Failed to reach target temperature".
1/30/2025
DRS_9195_v4_revF_11Dec2024
中文
PromethION
11th Dec 2024
- Updated kit content to include information on different RNA CS (RCS) vial concentration in new kit batches.
- Updated instructions to include options for lower RNA CS (RCS) concentration (old) and higher RNA CS (RCS) concentraction (new).
- Addition of links to MinION Mk1D IT requirements in "Compatibility of this protocol" and user manual in "Data acquisition and basecalling", "How to start sequencing".
- Arrow which was previously at the bottom edge of the flow cell in Image 1b "Priming and loading MinION/GridION Flow Cell" was moved to the middle of the flow cell.
- Updated link for flow cell returns in "Flow cell reuse and returns" and removed note for flushing flow cells.
- Updated link for EPI2ME in "Downstream analysis".
- Updated link for MinION temperature control in "Issues during a sequencing run", "Failed to reach target temperature".
1/27/2025
DRS_9195_v4_revF_11Dec2024
English
GridION
11th Dec 2024
- Updated kit content to include information on different RNA CS (RCS) vial concentration in new kit batches.
- Updated instructions to include options for lower RNA CS (RCS) concentration (old) and higher RNA CS (RCS) concentraction (new).
- Addition of links to MinION Mk1D IT requirements in "Compatibility of this protocol" and user manual in "Data acquisition and basecalling", "How to start sequencing".
- Arrow which was previously at the bottom edge of the flow cell in Image 1b "Priming and loading MinION/GridION Flow Cell" was moved to the middle of the flow cell.
- Updated link for flow cell returns in "Flow cell reuse and returns" and removed note for flushing flow cells.
- Updated link for EPI2ME in "Downstream analysis".
- Updated link for MinION temperature control in "Issues during a sequencing run", "Failed to reach target temperature".
1/27/2025
DRS_9195_v4_revF_11Dec2024
English
MinION
11th Dec 2024
- Updated kit content to include information on different RNA CS (RCS) vial concentration in new kit batches.
- Updated instructions to include options for lower RNA CS (RCS) concentration (old) and higher RNA CS (RCS) concentraction (new).
- Addition of links to MinION Mk1D IT requirements in "Compatibility of this protocol" and user manual in "Data acquisition and basecalling", "How to start sequencing".
- Arrow which was previously at the bottom edge of the flow cell in Image 1b "Priming and loading MinION/GridION Flow Cell" was moved to the middle of the flow cell.
- Updated link for flow cell returns in "Flow cell reuse and returns" and removed note for flushing flow cells.
- Updated link for EPI2ME in "Downstream analysis".
- Updated link for MinION temperature control in "Issues during a sequencing run", "Failed to reach target temperature".
1/27/2025
DRS_9195_v4_revF_11Dec2024
English
PromethION
11th Dec 2024
- Updated kit content to include information on different RNA CS (RCS) vial concentration in new kit batches.
- Updated instructions to include options for lower RNA CS (RCS) concentration (old) and higher RNA CS (RCS) concentraction (new).
- Addition of links to MinION Mk1D IT requirements in "Compatibility of this protocol" and user manual in "Data acquisition and basecalling", "How to start sequencing".
- Arrow which was previously at the bottom edge of the flow cell in Image 1b "Priming and loading MinION/GridION Flow Cell" was moved to the middle of the flow cell.
- Updated link for flow cell returns in "Flow cell reuse and returns" and removed note for flushing flow cells.
- Updated link for EPI2ME in "Downstream analysis".
- Updated link for MinION temperature control in "Issues during a sequencing run", "Failed to reach target temperature".
1/27/2025
DRS_9195_v4_revF_11Dec2024
Español
GridION
11th Dec 2024
- Updated kit content to include information on different RNA CS (RCS) vial concentration in new kit batches.
- Updated instructions to include options for lower RNA CS (RCS) concentration (old) and higher RNA CS (RCS) concentraction (new).
- Addition of links to MinION Mk1D IT requirements in "Compatibility of this protocol" and user manual in "Data acquisition and basecalling", "How to start sequencing".
- Arrow which was previously at the bottom edge of the flow cell in Image 1b "Priming and loading MinION/GridION Flow Cell" was moved to the middle of the flow cell.
- Updated link for flow cell returns in "Flow cell reuse and returns" and removed note for flushing flow cells.
- Updated link for EPI2ME in "Downstream analysis".
- Updated link for MinION temperature control in "Issues during a sequencing run", "Failed to reach target temperature".
1/27/2025
DRS_9195_v4_revF_11Dec2024
Español
MinION
11th Dec 2024
- Updated kit content to include information on different RNA CS (RCS) vial concentration in new kit batches.
- Updated instructions to include options for lower RNA CS (RCS) concentration (old) and higher RNA CS (RCS) concentraction (new).
- Addition of links to MinION Mk1D IT requirements in "Compatibility of this protocol" and user manual in "Data acquisition and basecalling", "How to start sequencing".
- Arrow which was previously at the bottom edge of the flow cell in Image 1b "Priming and loading MinION/GridION Flow Cell" was moved to the middle of the flow cell.
- Updated link for flow cell returns in "Flow cell reuse and returns" and removed note for flushing flow cells.
- Updated link for EPI2ME in "Downstream analysis".
- Updated link for MinION temperature control in "Issues during a sequencing run", "Failed to reach target temperature".
1/27/2025
DRS_9195_v4_revF_11Dec2024
Español
PromethION
11th Dec 2024
- Updated kit content to include information on different RNA CS (RCS) vial concentration in new kit batches.
- Updated instructions to include options for lower RNA CS (RCS) concentration (old) and higher RNA CS (RCS) concentraction (new).
- Addition of links to MinION Mk1D IT requirements in "Compatibility of this protocol" and user manual in "Data acquisition and basecalling", "How to start sequencing".
- Arrow which was previously at the bottom edge of the flow cell in Image 1b "Priming and loading MinION/GridION Flow Cell" was moved to the middle of the flow cell.
- Updated link for flow cell returns in "Flow cell reuse and returns" and removed note for flushing flow cells.
- Updated link for EPI2ME in "Downstream analysis".
- Updated link for MinION temperature control in "Issues during a sequencing run", "Failed to reach target temperature".
1/27/2025
DRS_9195_v4_revF_11Dec2024
中文
GridION
11th Dec 2024
- Updated kit content to include information on different RNA CS (RCS) vial concentration in new kit batches.
- Updated instructions to include options for lower RNA CS (RCS) concentration (old) and higher RNA CS (RCS) concentraction (new).
- Addition of links to MinION Mk1D IT requirements in "Compatibility of this protocol" and user manual in "Data acquisition and basecalling", "How to start sequencing".
- Arrow which was previously at the bottom edge of the flow cell in Image 1b "Priming and loading MinION/GridION Flow Cell" was moved to the middle of the flow cell.
- Updated link for flow cell returns in "Flow cell reuse and returns" and removed note for flushing flow cells.
- Updated link for EPI2ME in "Downstream analysis".
- Updated link for MinION temperature control in "Issues during a sequencing run", "Failed to reach target temperature".
1/27/2025
DRS_9195_v4_revF_11Dec2024
中文
MinION
11th Dec 2024
- Updated kit content to include information on different RNA CS (RCS) vial concentration in new kit batches.
- Updated instructions to include options for lower RNA CS (RCS) concentration (old) and higher RNA CS (RCS) concentraction (new).
- Addition of links to MinION Mk1D IT requirements in "Compatibility of this protocol" and user manual in "Data acquisition and basecalling", "How to start sequencing".
- Arrow which was previously at the bottom edge of the flow cell in Image 1b "Priming and loading MinION/GridION Flow Cell" was moved to the middle of the flow cell.
- Updated link for flow cell returns in "Flow cell reuse and returns" and removed note for flushing flow cells.
- Updated link for EPI2ME in "Downstream analysis".
- Updated link for MinION temperature control in "Issues during a sequencing run", "Failed to reach target temperature".
1/27/2025
DRS_9195_v4_revF_11Dec2024
中文
PromethION
11th Dec 2024
- Updated kit content to include information on different RNA CS (RCS) vial concentration in new kit batches.
- Updated instructions to include options for lower RNA CS (RCS) concentration (old) and higher RNA CS (RCS) concentraction (new).
- Addition of links to MinION Mk1D IT requirements in "Compatibility of this protocol" and user manual in "Data acquisition and basecalling", "How to start sequencing".
- Arrow which was previously at the bottom edge of the flow cell in Image 1b "Priming and loading MinION/GridION Flow Cell" was moved to the middle of the flow cell.
- Updated link for flow cell returns in "Flow cell reuse and returns" and removed note for flushing flow cells.
- Updated link for EPI2ME in "Downstream analysis".
- Updated link for MinION temperature control in "Issues during a sequencing run", "Failed to reach target temperature".
12/14/2024
DRS_9195_v4_revF_11Dec2024
English
GridION
11th Dec 2024
- Updated kit content to include information on different RNA CS (RCS) vial concentration in new kit batches.
- Updated instructions to include options for lower RNA CS (RCS) concentration (old) and higher RNA CS (RCS) concentraction (new).
- Addition of links to MinION Mk1D IT requirements in "Compatibility of this protocol" and user manual in "Data acquisition and basecalling", "How to start sequencing".
- Arrow which was previously at the bottom edge of the flow cell in Image 1b "Priming and loading MinION/GridION Flow Cell" was moved to the middle of the flow cell.
- Updated link for flow cell returns in "Flow cell reuse and returns" and removed note for flushing flow cells.
- Updated link for EPI2ME in "Downstream analysis".
- Updated link for MinION temperature control in "Issues during a sequencing run", "Failed to reach target temperature".
12/14/2024
DRS_9195_v4_revF_11Dec2024
English
MinION
11th Dec 2024
- Updated kit content to include information on different RNA CS (RCS) vial concentration in new kit batches.
- Updated instructions to include options for lower RNA CS (RCS) concentration (old) and higher RNA CS (RCS) concentraction (new).
- Addition of links to MinION Mk1D IT requirements in "Compatibility of this protocol" and user manual in "Data acquisition and basecalling", "How to start sequencing".
- Arrow which was previously at the bottom edge of the flow cell in Image 1b "Priming and loading MinION/GridION Flow Cell" was moved to the middle of the flow cell.
- Updated link for flow cell returns in "Flow cell reuse and returns" and removed note for flushing flow cells.
- Updated link for EPI2ME in "Downstream analysis".
- Updated link for MinION temperature control in "Issues during a sequencing run", "Failed to reach target temperature".
12/14/2024
DRS_9195_v4_revF_11Dec2024
English
PromethION
11th Dec 2024
- Updated kit content to include information on different RNA CS (RCS) vial concentration in new kit batches.
- Updated instructions to include options for lower RNA CS (RCS) concentration (old) and higher RNA CS (RCS) concentraction (new).
- Addition of links to MinION Mk1D IT requirements in "Compatibility of this protocol" and user manual in "Data acquisition and basecalling", "How to start sequencing".
- Arrow which was previously at the bottom edge of the flow cell in Image 1b "Priming and loading MinION/GridION Flow Cell" was moved to the middle of the flow cell.
- Updated link for flow cell returns in "Flow cell reuse and returns" and removed note for flushing flow cells.
- Updated link for EPI2ME in "Downstream analysis".
- Updated link for MinION temperature control in "Issues during a sequencing run", "Failed to reach target temperature".
12/14/2024
DRS_9195_v4_revF_11Dec2024
Español
GridION
11th Dec 2024
- Updated kit content to include information on different RNA CS (RCS) vial concentration in new kit batches.
- Updated instructions to include options for lower RNA CS (RCS) concentration (old) and higher RNA CS (RCS) concentraction (new).
- Addition of links to MinION Mk1D IT requirements in "Compatibility of this protocol" and user manual in "Data acquisition and basecalling", "How to start sequencing".
- Arrow which was previously at the bottom edge of the flow cell in Image 1b "Priming and loading MinION/GridION Flow Cell" was moved to the middle of the flow cell.
- Updated link for flow cell returns in "Flow cell reuse and returns" and removed note for flushing flow cells.
- Updated link for EPI2ME in "Downstream analysis".
- Updated link for MinION temperature control in "Issues during a sequencing run", "Failed to reach target temperature".
12/14/2024
DRS_9195_v4_revF_11Dec2024
Español
MinION
11th Dec 2024
- Updated kit content to include information on different RNA CS (RCS) vial concentration in new kit batches.
- Updated instructions to include options for lower RNA CS (RCS) concentration (old) and higher RNA CS (RCS) concentraction (new).
- Addition of links to MinION Mk1D IT requirements in "Compatibility of this protocol" and user manual in "Data acquisition and basecalling", "How to start sequencing".
- Arrow which was previously at the bottom edge of the flow cell in Image 1b "Priming and loading MinION/GridION Flow Cell" was moved to the middle of the flow cell.
- Updated link for flow cell returns in "Flow cell reuse and returns" and removed note for flushing flow cells.
- Updated link for EPI2ME in "Downstream analysis".
- Updated link for MinION temperature control in "Issues during a sequencing run", "Failed to reach target temperature".
12/14/2024
DRS_9195_v4_revF_11Dec2024
Español
PromethION
11th Dec 2024
- Updated kit content to include information on different RNA CS (RCS) vial concentration in new kit batches.
- Updated instructions to include options for lower RNA CS (RCS) concentration (old) and higher RNA CS (RCS) concentraction (new).
- Addition of links to MinION Mk1D IT requirements in "Compatibility of this protocol" and user manual in "Data acquisition and basecalling", "How to start sequencing".
- Arrow which was previously at the bottom edge of the flow cell in Image 1b "Priming and loading MinION/GridION Flow Cell" was moved to the middle of the flow cell.
- Updated link for flow cell returns in "Flow cell reuse and returns" and removed note for flushing flow cells.
- Updated link for EPI2ME in "Downstream analysis".
- Updated link for MinION temperature control in "Issues during a sequencing run", "Failed to reach target temperature".
12/14/2024
DRS_9195_v4_revF_11Dec2024
中文
GridION
11th Dec 2024
- Updated kit content to include information on different RNA CS (RCS) vial concentration in new kit batches.
- Updated instructions to include options for lower RNA CS (RCS) concentration (old) and higher RNA CS (RCS) concentraction (new).
- Addition of links to MinION Mk1D IT requirements in "Compatibility of this protocol" and user manual in "Data acquisition and basecalling", "How to start sequencing".
- Arrow which was previously at the bottom edge of the flow cell in Image 1b "Priming and loading MinION/GridION Flow Cell" was moved to the middle of the flow cell.
- Updated link for flow cell returns in "Flow cell reuse and returns" and removed note for flushing flow cells.
- Updated link for EPI2ME in "Downstream analysis".
- Updated link for MinION temperature control in "Issues during a sequencing run", "Failed to reach target temperature".
12/14/2024
DRS_9195_v4_revF_11Dec2024
中文
MinION
11th Dec 2024
- Updated kit content to include information on different RNA CS (RCS) vial concentration in new kit batches.
- Updated instructions to include options for lower RNA CS (RCS) concentration (old) and higher RNA CS (RCS) concentraction (new).
- Addition of links to MinION Mk1D IT requirements in "Compatibility of this protocol" and user manual in "Data acquisition and basecalling", "How to start sequencing".
- Arrow which was previously at the bottom edge of the flow cell in Image 1b "Priming and loading MinION/GridION Flow Cell" was moved to the middle of the flow cell.
- Updated link for flow cell returns in "Flow cell reuse and returns" and removed note for flushing flow cells.
- Updated link for EPI2ME in "Downstream analysis".
- Updated link for MinION temperature control in "Issues during a sequencing run", "Failed to reach target temperature".
12/14/2024
DRS_9195_v4_revF_11Dec2024
中文
PromethION
11th Dec 2024
- Updated kit content to include information on different RNA CS (RCS) vial concentration in new kit batches.
- Updated instructions to include options for lower RNA CS (RCS) concentration (old) and higher RNA CS (RCS) concentraction (new).
- Addition of links to MinION Mk1D IT requirements in "Compatibility of this protocol" and user manual in "Data acquisition and basecalling", "How to start sequencing".
- Arrow which was previously at the bottom edge of the flow cell in Image 1b "Priming and loading MinION/GridION Flow Cell" was moved to the middle of the flow cell.
- Updated link for flow cell returns in "Flow cell reuse and returns" and removed note for flushing flow cells.
- Updated link for EPI2ME in "Downstream analysis".
- Updated link for MinION temperature control in "Issues during a sequencing run", "Failed to reach target temperature".
12/11/2024
DRS_9195_v4_revF_11Dec2024
English
GridION
11th Dec 2024
- Updated kit content to include information on different RNA CS (RCS) vial concentration in new kit batches.
- Updated instructions to include options for lower RNA CS (RCS) concentration (old) and higher RNA CS (RCS) concentraction (new).
- Addition of links to MinION Mk1D IT requirements in "Compatibility of this protocol" and user manual in "Data acquisition and basecalling", "How to start sequencing".
- Arrow which was previously at the bottom edge of the flow cell in Image 1b "Priming and loading MinION/GridION Flow Cell" was moved to the middle of the flow cell.
- Updated link for flow cell returns in "Flow cell reuse and returns" and removed note for flushing flow cells.
- Updated link for EPI2ME in "Downstream analysis".
- Updated link for MinION temperature control in "Issues during a sequencing run", "Failed to reach target temperature".
12/11/2024
DRS_9195_v4_revF_11Dec2024
English
MinION
11th Dec 2024
- Updated kit content to include information on different RNA CS (RCS) vial concentration in new kit batches.
- Updated instructions to include options for lower RNA CS (RCS) concentration (old) and higher RNA CS (RCS) concentraction (new).
- Addition of links to MinION Mk1D IT requirements in "Compatibility of this protocol" and user manual in "Data acquisition and basecalling", "How to start sequencing".
- Arrow which was previously at the bottom edge of the flow cell in Image 1b "Priming and loading MinION/GridION Flow Cell" was moved to the middle of the flow cell.
- Updated link for flow cell returns in "Flow cell reuse and returns" and removed note for flushing flow cells.
- Updated link for EPI2ME in "Downstream analysis".
- Updated link for MinION temperature control in "Issues during a sequencing run", "Failed to reach target temperature".
12/11/2024
DRS_9195_v4_revF_11Dec2024
English
PromethION
11th Dec 2024
- Updated kit content to include information on different RNA CS (RCS) vial concentration in new kit batches.
- Updated instructions to include options for lower RNA CS (RCS) concentration (old) and higher RNA CS (RCS) concentraction (new).
- Addition of links to MinION Mk1D IT requirements in "Compatibility of this protocol" and user manual in "Data acquisition and basecalling", "How to start sequencing".
- Arrow which was previously at the bottom edge of the flow cell in Image 1b "Priming and loading MinION/GridION Flow Cell" was moved to the middle of the flow cell.
- Updated link for flow cell returns in "Flow cell reuse and returns" and removed note for flushing flow cells.
- Updated link for EPI2ME in "Downstream analysis".
- Updated link for MinION temperature control in "Issues during a sequencing run", "Failed to reach target temperature".
12/11/2024
DRS_9195_v4_revF_11Dec2024
Español
GridION
11th Dec 2024
- Updated kit content to include information on different RNA CS (RCS) vial concentration in new kit batches.
- Updated instructions to include options for lower RNA CS (RCS) concentration (old) and higher RNA CS (RCS) concentraction (new).
- Addition of links to MinION Mk1D IT requirements in "Compatibility of this protocol" and user manual in "Data acquisition and basecalling", "How to start sequencing".
- Arrow which was previously at the bottom edge of the flow cell in Image 1b "Priming and loading MinION/GridION Flow Cell" was moved to the middle of the flow cell.
- Updated link for flow cell returns in "Flow cell reuse and returns" and removed note for flushing flow cells.
- Updated link for EPI2ME in "Downstream analysis".
- Updated link for MinION temperature control in "Issues during a sequencing run", "Failed to reach target temperature".
12/11/2024
DRS_9195_v4_revF_11Dec2024
Español
MinION
11th Dec 2024
- Updated kit content to include information on different RNA CS (RCS) vial concentration in new kit batches.
- Updated instructions to include options for lower RNA CS (RCS) concentration (old) and higher RNA CS (RCS) concentraction (new).
- Addition of links to MinION Mk1D IT requirements in "Compatibility of this protocol" and user manual in "Data acquisition and basecalling", "How to start sequencing".
- Arrow which was previously at the bottom edge of the flow cell in Image 1b "Priming and loading MinION/GridION Flow Cell" was moved to the middle of the flow cell.
- Updated link for flow cell returns in "Flow cell reuse and returns" and removed note for flushing flow cells.
- Updated link for EPI2ME in "Downstream analysis".
- Updated link for MinION temperature control in "Issues during a sequencing run", "Failed to reach target temperature".
12/11/2024
DRS_9195_v4_revF_11Dec2024
Español
PromethION
11th Dec 2024
- Updated kit content to include information on different RNA CS (RCS) vial concentration in new kit batches.
- Updated instructions to include options for lower RNA CS (RCS) concentration (old) and higher RNA CS (RCS) concentraction (new).
- Addition of links to MinION Mk1D IT requirements in "Compatibility of this protocol" and user manual in "Data acquisition and basecalling", "How to start sequencing".
- Arrow which was previously at the bottom edge of the flow cell in Image 1b "Priming and loading MinION/GridION Flow Cell" was moved to the middle of the flow cell.
- Updated link for flow cell returns in "Flow cell reuse and returns" and removed note for flushing flow cells.
- Updated link for EPI2ME in "Downstream analysis".
- Updated link for MinION temperature control in "Issues during a sequencing run", "Failed to reach target temperature".
12/11/2024
DRS_9195_v4_revF_11Dec2024
中文
GridION
11th Dec 2024
- Updated kit content to include information on different RNA CS (RCS) vial concentration in new kit batches.
- Updated instructions to include options for lower RNA CS (RCS) concentration (old) and higher RNA CS (RCS) concentraction (new).
- Addition of links to MinION Mk1D IT requirements in "Compatibility of this protocol" and user manual in "Data acquisition and basecalling", "How to start sequencing".
- Arrow which was previously at the bottom edge of the flow cell in Image 1b "Priming and loading MinION/GridION Flow Cell" was moved to the middle of the flow cell.
- Updated link for flow cell returns in "Flow cell reuse and returns" and removed note for flushing flow cells.
- Updated link for EPI2ME in "Downstream analysis".
- Updated link for MinION temperature control in "Issues during a sequencing run", "Failed to reach target temperature".
12/11/2024
DRS_9195_v4_revF_11Dec2024
中文
MinION
11th Dec 2024
- Updated kit content to include information on different RNA CS (RCS) vial concentration in new kit batches.
- Updated instructions to include options for lower RNA CS (RCS) concentration (old) and higher RNA CS (RCS) concentraction (new).
- Addition of links to MinION Mk1D IT requirements in "Compatibility of this protocol" and user manual in "Data acquisition and basecalling", "How to start sequencing".
- Arrow which was previously at the bottom edge of the flow cell in Image 1b "Priming and loading MinION/GridION Flow Cell" was moved to the middle of the flow cell.
- Updated link for flow cell returns in "Flow cell reuse and returns" and removed note for flushing flow cells.
- Updated link for EPI2ME in "Downstream analysis".
- Updated link for MinION temperature control in "Issues during a sequencing run", "Failed to reach target temperature".
12/11/2024
DRS_9195_v4_revF_11Dec2024
中文
PromethION
11th Dec 2024
- Updated kit content to include information on different RNA CS (RCS) vial concentration in new kit batches.
- Updated instructions to include options for lower RNA CS (RCS) concentration (old) and higher RNA CS (RCS) concentraction (new).
- Addition of links to MinION Mk1D IT requirements in "Compatibility of this protocol" and user manual in "Data acquisition and basecalling", "How to start sequencing".
- Arrow which was previously at the bottom edge of the flow cell in Image 1b "Priming and loading MinION/GridION Flow Cell" was moved to the middle of the flow cell.
- Updated link for flow cell returns in "Flow cell reuse and returns" and removed note for flushing flow cells.
- Updated link for EPI2ME in "Downstream analysis".
- Updated link for MinION temperature control in "Issues during a sequencing run", "Failed to reach target temperature".
10/16/2024
DRS_9195_v4_revE_23Sep2024
English
GridION
23 Sept 2024
- Updated step 18 in Library preparation with clearer wording for the method.
- Updated name of the step "Priming and loading the SpotON flow cell" to "Priming and loading the MinION and GridION flow cell".
10/16/2024
DRS_9195_v4_revE_23Sep2024
English
MinION
23 Sept 2024
- Updated step 18 in Library preparation with clearer wording for the method.
- Updated name of the step "Priming and loading the SpotON flow cell" to "Priming and loading the MinION and GridION flow cell".
10/16/2024
DRS_9195_v4_revE_23Sep2024
English
PromethION
23 Sept 2024
- Updated step 18 in Library preparation with clearer wording for the method.
- Updated name of the step "Priming and loading the SpotON flow cell" to "Priming and loading the MinION and GridION flow cell".
10/16/2024
DRS_9195_v4_revE_23Sep2024
Español
GridION
23 Sept 2024
- Updated step 18 in Library preparation with clearer wording for the method.
- Updated name of the step "Priming and loading the SpotON flow cell" to "Priming and loading the MinION and GridION flow cell".
10/16/2024
DRS_9195_v4_revE_23Sep2024
Español
MinION
23 Sept 2024
- Updated step 18 in Library preparation with clearer wording for the method.
- Updated name of the step "Priming and loading the SpotON flow cell" to "Priming and loading the MinION and GridION flow cell".
10/16/2024
DRS_9195_v4_revE_23Sep2024
Español
PromethION
23 Sept 2024
- Updated step 18 in Library preparation with clearer wording for the method.
- Updated name of the step "Priming and loading the SpotON flow cell" to "Priming and loading the MinION and GridION flow cell".
10/16/2024
DRS_9195_v4_revE_23Sep2024
中文
GridION
23 Sept 2024
- Updated step 18 in Library preparation with clearer wording for the method.
- Updated name of the step "Priming and loading the SpotON flow cell" to "Priming and loading the MinION and GridION flow cell".
10/16/2024
DRS_9195_v4_revE_23Sep2024
中文
MinION
23 Sept 2024
- Updated step 18 in Library preparation with clearer wording for the method.
- Updated name of the step "Priming and loading the SpotON flow cell" to "Priming and loading the MinION and GridION flow cell".
10/16/2024
DRS_9195_v4_revE_23Sep2024
中文
PromethION
23 Sept 2024
- Updated step 18 in Library preparation with clearer wording for the method.
- Updated name of the step "Priming and loading the SpotON flow cell" to "Priming and loading the MinION and GridION flow cell".
10/16/2024
DRS_9195_v4_revE_23Sep2024
English
GridION
23 Sept 2024
- Updated step 18 in Library preparation with clearer wording for the method.
- Updated name of the step "Priming and loading the SpotON flow cell" to "Priming and loading the MinION and GridION flow cell".
10/16/2024
DRS_9195_v4_revE_23Sep2024
English
MinION
23 Sept 2024
- Updated step 18 in Library preparation with clearer wording for the method.
- Updated name of the step "Priming and loading the SpotON flow cell" to "Priming and loading the MinION and GridION flow cell".
10/16/2024
DRS_9195_v4_revE_23Sep2024
English
PromethION
23 Sept 2024
- Updated step 18 in Library preparation with clearer wording for the method.
- Updated name of the step "Priming and loading the SpotON flow cell" to "Priming and loading the MinION and GridION flow cell".
10/16/2024
DRS_9195_v4_revE_23Sep2024
Español
GridION
23 Sept 2024
- Updated step 18 in Library preparation with clearer wording for the method.
- Updated name of the step "Priming and loading the SpotON flow cell" to "Priming and loading the MinION and GridION flow cell".
10/16/2024
DRS_9195_v4_revE_23Sep2024
Español
MinION
23 Sept 2024
- Updated step 18 in Library preparation with clearer wording for the method.
- Updated name of the step "Priming and loading the SpotON flow cell" to "Priming and loading the MinION and GridION flow cell".
10/16/2024
DRS_9195_v4_revE_23Sep2024
Español
PromethION
23 Sept 2024
- Updated step 18 in Library preparation with clearer wording for the method.
- Updated name of the step "Priming and loading the SpotON flow cell" to "Priming and loading the MinION and GridION flow cell".
10/16/2024
DRS_9195_v4_revE_23Sep2024
中文
GridION
23 Sept 2024
- Updated step 18 in Library preparation with clearer wording for the method.
- Updated name of the step "Priming and loading the SpotON flow cell" to "Priming and loading the MinION and GridION flow cell".
10/16/2024
DRS_9195_v4_revE_23Sep2024
中文
MinION
23 Sept 2024
- Updated step 18 in Library preparation with clearer wording for the method.
- Updated name of the step "Priming and loading the SpotON flow cell" to "Priming and loading the MinION and GridION flow cell".
10/16/2024
DRS_9195_v4_revE_23Sep2024
中文
PromethION
23 Sept 2024
- Updated step 18 in Library preparation with clearer wording for the method.
- Updated name of the step "Priming and loading the SpotON flow cell" to "Priming and loading the MinION and GridION flow cell".
10/16/2024
DRS_9195_v4_revE_23Sep2024
English
GridION
23 Sept 2024
- Updated step 18 in Library preparation with clearer wording for the method.
- Updated name of the step "Priming and loading the SpotON flow cell" to "Priming and loading the MinION and GridION flow cell".
10/16/2024
DRS_9195_v4_revE_23Sep2024
English
MinION
23 Sept 2024
- Updated step 18 in Library preparation with clearer wording for the method.
- Updated name of the step "Priming and loading the SpotON flow cell" to "Priming and loading the MinION and GridION flow cell".
10/16/2024
DRS_9195_v4_revE_23Sep2024
English
PromethION
23 Sept 2024
- Updated step 18 in Library preparation with clearer wording for the method.
- Updated name of the step "Priming and loading the SpotON flow cell" to "Priming and loading the MinION and GridION flow cell".
10/16/2024
DRS_9195_v4_revE_23Sep2024
中文
GridION
23 Sept 2024
- Updated step 18 in Library preparation with clearer wording for the method.
- Updated name of the step "Priming and loading the SpotON flow cell" to "Priming and loading the MinION and GridION flow cell".
10/16/2024
DRS_9195_v4_revE_23Sep2024
中文
MinION
23 Sept 2024
- Updated step 18 in Library preparation with clearer wording for the method.
- Updated name of the step "Priming and loading the SpotON flow cell" to "Priming and loading the MinION and GridION flow cell".
10/16/2024
DRS_9195_v4_revE_23Sep2024
中文
PromethION
23 Sept 2024
- Updated step 18 in Library preparation with clearer wording for the method.
- Updated name of the step "Priming and loading the SpotON flow cell" to "Priming and loading the MinION and GridION flow cell".
10/14/2024
DRS_9195_v4_revE_23Sep2024
English
GridION
23 Sept 2024
- Updated step 18 in Library preparation with clearer wording for the method.
- Updated name of the step "Priming and loading the SpotON flow cell" to "Priming and loading the MinION and GridION flow cell".
10/14/2024
DRS_9195_v4_revE_23Sep2024
English
MinION
23 Sept 2024
- Updated step 18 in Library preparation with clearer wording for the method.
- Updated name of the step "Priming and loading the SpotON flow cell" to "Priming and loading the MinION and GridION flow cell".
10/14/2024
DRS_9195_v4_revE_23Sep2024
English
PromethION
23 Sept 2024
- Updated step 18 in Library preparation with clearer wording for the method.
- Updated name of the step "Priming and loading the SpotON flow cell" to "Priming and loading the MinION and GridION flow cell".
10/14/2024
DRS_9195_v4_revE_23Sep2024
中文
GridION
23 Sept 2024
- Updated step 18 in Library preparation with clearer wording for the method.
- Updated name of the step "Priming and loading the SpotON flow cell" to "Priming and loading the MinION and GridION flow cell".
10/14/2024
DRS_9195_v4_revE_23Sep2024
中文
MinION
23 Sept 2024
- Updated step 18 in Library preparation with clearer wording for the method.
- Updated name of the step "Priming and loading the SpotON flow cell" to "Priming and loading the MinION and GridION flow cell".
10/14/2024
DRS_9195_v4_revE_23Sep2024
中文
PromethION
23 Sept 2024
- Updated step 18 in Library preparation with clearer wording for the method.
- Updated name of the step "Priming and loading the SpotON flow cell" to "Priming and loading the MinION and GridION flow cell".
10/11/2024
DRS_9195_v4_revE_23Sep2024
English
GridION
23 Sept 2024
- Updated step 18 in Library preparation with clearer wording for the method.
- Updated name of the step "Priming and loading the SpotON flow cell" to "Priming and loading the MinION and GridION flow cell".
10/11/2024
DRS_9195_v4_revE_23Sep2024
English
MinION
23 Sept 2024
- Updated step 18 in Library preparation with clearer wording for the method.
- Updated name of the step "Priming and loading the SpotON flow cell" to "Priming and loading the MinION and GridION flow cell".
10/11/2024
DRS_9195_v4_revE_23Sep2024
English
PromethION
23 Sept 2024
- Updated step 18 in Library preparation with clearer wording for the method.
- Updated name of the step "Priming and loading the SpotON flow cell" to "Priming and loading the MinION and GridION flow cell".
10/11/2024
DRS_9195_v4_revE_23Sep2024
中文
GridION
23 Sept 2024
- Updated step 18 in Library preparation with clearer wording for the method.
- Updated name of the step "Priming and loading the SpotON flow cell" to "Priming and loading the MinION and GridION flow cell".
10/11/2024
DRS_9195_v4_revE_23Sep2024
中文
MinION
23 Sept 2024
- Updated step 18 in Library preparation with clearer wording for the method.
- Updated name of the step "Priming and loading the SpotON flow cell" to "Priming and loading the MinION and GridION flow cell".
10/11/2024
DRS_9195_v4_revE_23Sep2024
中文
PromethION
23 Sept 2024
- Updated step 18 in Library preparation with clearer wording for the method.
- Updated name of the step "Priming and loading the SpotON flow cell" to "Priming and loading the MinION and GridION flow cell".
10/11/2024
DRS_9195_v4_revE_23Sep2024
English
GridION
23 Sept 2024
- Updated step 18 in Library preparation with clearer wording for the method.
- Updated name of the step "Priming and loading the SpotON flow cell" to "Priming and loading the MinION and GridION flow cell".
10/11/2024
DRS_9195_v4_revE_23Sep2024
English
MinION
23 Sept 2024
- Updated step 18 in Library preparation with clearer wording for the method.
- Updated name of the step "Priming and loading the SpotON flow cell" to "Priming and loading the MinION and GridION flow cell".
10/11/2024
DRS_9195_v4_revE_23Sep2024
English
PromethION
23 Sept 2024
- Updated step 18 in Library preparation with clearer wording for the method.
- Updated name of the step "Priming and loading the SpotON flow cell" to "Priming and loading the MinION and GridION flow cell".
10/11/2024
DRS_9195_v4_revE_23Sep2024
中文
GridION
23 Sept 2024
- Updated step 18 in Library preparation with clearer wording for the method.
- Updated name of the step "Priming and loading the SpotON flow cell" to "Priming and loading the MinION and GridION flow cell".
10/11/2024
DRS_9195_v4_revE_23Sep2024
中文
MinION
23 Sept 2024
- Updated step 18 in Library preparation with clearer wording for the method.
- Updated name of the step "Priming and loading the SpotON flow cell" to "Priming and loading the MinION and GridION flow cell".
10/11/2024
DRS_9195_v4_revE_23Sep2024
中文
PromethION
23 Sept 2024
- Updated step 18 in Library preparation with clearer wording for the method.
- Updated name of the step "Priming and loading the SpotON flow cell" to "Priming and loading the MinION and GridION flow cell".
9/23/2024
DRS_9195_v4_revE_23Sep2024
English
GridION
23 Sept 2024
- Updated step 18 in Library preparation with clearer wording for the method.
- Updated name of the step "Priming and loading the SpotON flow cell" to "Priming and loading the MinION and GridION flow cell".
9/23/2024
DRS_9195_v4_revE_23Sep2024
English
MinION
23 Sept 2024
- Updated step 18 in Library preparation with clearer wording for the method.
- Updated name of the step "Priming and loading the SpotON flow cell" to "Priming and loading the MinION and GridION flow cell".
9/23/2024
DRS_9195_v4_revE_23Sep2024
English
PromethION
23 Sept 2024
- Updated step 18 in Library preparation with clearer wording for the method.
- Updated name of the step "Priming and loading the SpotON flow cell" to "Priming and loading the MinION and GridION flow cell".
9/23/2024
DRS_9195_v4_revE_23Sep2024
中文
GridION
23 Sept 2024
- Updated step 18 in Library preparation with clearer wording for the method.
- Updated name of the step "Priming and loading the SpotON flow cell" to "Priming and loading the MinION and GridION flow cell".
9/23/2024
DRS_9195_v4_revE_23Sep2024
中文
MinION
23 Sept 2024
- Updated step 18 in Library preparation with clearer wording for the method.
- Updated name of the step "Priming and loading the SpotON flow cell" to "Priming and loading the MinION and GridION flow cell".
9/23/2024
DRS_9195_v4_revE_23Sep2024
中文
PromethION
23 Sept 2024
- Updated step 18 in Library preparation with clearer wording for the method.
- Updated name of the step "Priming and loading the SpotON flow cell" to "Priming and loading the MinION and GridION flow cell".
8/27/2024
DRS_9195_v4_revD_20Sep2023
English
GridION
31 July 2024
- Updated the protocol format to the new "slimmed-down" introduction sections.
- Updated workflow image in introduction to fix formatting errors in PDF generation
- Updated the Reverse transcriptase reagents and steps to the new method using Induro® Reverse Transcriptase (NEB, cat # M0681).
- Updated the RNase Inhibitor reagents and steps to the new method using Murine RNase Inhibitor (NEB, M0314).
- Updated first Agencourt RNAClean XP bead clean in Library Preparation section to elute into 23 ul Nuclease-free water, retain the full 23 ul and no longer have to add 3 ul of water in the next step.
- Updated "Flow cell reuse and returns" section to specify compatibility and use-cases for the Flow Cell Wash Kit with the RNA sequencing kit and RNA flow cells.
8/27/2024
DRS_9195_v4_revD_20Sep2023
English
MinION
31 July 2024
- Updated the protocol format to the new "slimmed-down" introduction sections.
- Updated workflow image in introduction to fix formatting errors in PDF generation
- Updated the Reverse transcriptase reagents and steps to the new method using Induro® Reverse Transcriptase (NEB, cat # M0681).
- Updated the RNase Inhibitor reagents and steps to the new method using Murine RNase Inhibitor (NEB, M0314).
- Updated first Agencourt RNAClean XP bead clean in Library Preparation section to elute into 23 ul Nuclease-free water, retain the full 23 ul and no longer have to add 3 ul of water in the next step.
- Updated "Flow cell reuse and returns" section to specify compatibility and use-cases for the Flow Cell Wash Kit with the RNA sequencing kit and RNA flow cells.
8/27/2024
DRS_9195_v4_revD_20Sep2023
English
PromethION
31 July 2024
- Updated the protocol format to the new "slimmed-down" introduction sections.
- Updated workflow image in introduction to fix formatting errors in PDF generation
- Updated the Reverse transcriptase reagents and steps to the new method using Induro® Reverse Transcriptase (NEB, cat # M0681).
- Updated the RNase Inhibitor reagents and steps to the new method using Murine RNase Inhibitor (NEB, M0314).
- Updated first Agencourt RNAClean XP bead clean in Library Preparation section to elute into 23 ul Nuclease-free water, retain the full 23 ul and no longer have to add 3 ul of water in the next step.
- Updated "Flow cell reuse and returns" section to specify compatibility and use-cases for the Flow Cell Wash Kit with the RNA sequencing kit and RNA flow cells.
8/27/2024
DRS_9195_v4_revD_20Sep2023
中文
GridION
31 July 2024
- Updated the protocol format to the new "slimmed-down" introduction sections.
- Updated workflow image in introduction to fix formatting errors in PDF generation
- Updated the Reverse transcriptase reagents and steps to the new method using Induro® Reverse Transcriptase (NEB, cat # M0681).
- Updated the RNase Inhibitor reagents and steps to the new method using Murine RNase Inhibitor (NEB, M0314).
- Updated first Agencourt RNAClean XP bead clean in Library Preparation section to elute into 23 ul Nuclease-free water, retain the full 23 ul and no longer have to add 3 ul of water in the next step.
- Updated "Flow cell reuse and returns" section to specify compatibility and use-cases for the Flow Cell Wash Kit with the RNA sequencing kit and RNA flow cells.
8/27/2024
DRS_9195_v4_revD_20Sep2023
中文
MinION
31 July 2024
- Updated the protocol format to the new "slimmed-down" introduction sections.
- Updated workflow image in introduction to fix formatting errors in PDF generation
- Updated the Reverse transcriptase reagents and steps to the new method using Induro® Reverse Transcriptase (NEB, cat # M0681).
- Updated the RNase Inhibitor reagents and steps to the new method using Murine RNase Inhibitor (NEB, M0314).
- Updated first Agencourt RNAClean XP bead clean in Library Preparation section to elute into 23 ul Nuclease-free water, retain the full 23 ul and no longer have to add 3 ul of water in the next step.
- Updated "Flow cell reuse and returns" section to specify compatibility and use-cases for the Flow Cell Wash Kit with the RNA sequencing kit and RNA flow cells.
8/27/2024
DRS_9195_v4_revD_20Sep2023
中文
PromethION
31 July 2024
- Updated the protocol format to the new "slimmed-down" introduction sections.
- Updated workflow image in introduction to fix formatting errors in PDF generation
- Updated the Reverse transcriptase reagents and steps to the new method using Induro® Reverse Transcriptase (NEB, cat # M0681).
- Updated the RNase Inhibitor reagents and steps to the new method using Murine RNase Inhibitor (NEB, M0314).
- Updated first Agencourt RNAClean XP bead clean in Library Preparation section to elute into 23 ul Nuclease-free water, retain the full 23 ul and no longer have to add 3 ul of water in the next step.
- Updated "Flow cell reuse and returns" section to specify compatibility and use-cases for the Flow Cell Wash Kit with the RNA sequencing kit and RNA flow cells.
31 July 2024
- Updated the protocol format to the new "slimmed-down" introduction sections.
- Updated workflow image in introduction to fix formatting errors in PDF generation
- Updated the Reverse transcriptase reagents and steps to the new method using Induro® Reverse Transcriptase (NEB, cat # M0681).
- Updated the RNase Inhibitor reagents and steps to the new method using Murine RNase Inhibitor (NEB, M0314).
- Updated first Agencourt RNAClean XP bead clean in Library Preparation section to elute into 23 ul Nuclease-free water, retain the full 23 ul and no longer have to add 3 ul of water in the next step.
- Updated "Flow cell reuse and returns" section to specify compatibility and use-cases for the Flow Cell Wash Kit with the RNA sequencing kit and RNA flow cells.
31 July 2024
- Updated the protocol format to the new "slimmed-down" introduction sections.
- Updated workflow image in introduction to fix formatting errors in PDF generation
- Updated the Reverse transcriptase reagents and steps to the new method using Induro® Reverse Transcriptase (NEB, cat # M0681).
- Updated the RNase Inhibitor reagents and steps to the new method using Murine RNase Inhibitor (NEB, M0314).
- Updated first Agencourt RNAClean XP bead clean in Library Preparation section to elute into 23 ul Nuclease-free water, retain the full 23 ul and no longer have to add 3 ul of water in the next step.
- Updated "Flow cell reuse and returns" section to specify compatibility and use-cases for the Flow Cell Wash Kit with the RNA sequencing kit and RNA flow cells.
31 July 2024
- Updated the protocol format to the new "slimmed-down" introduction sections.
- Updated workflow image in introduction to fix formatting errors in PDF generation
- Updated the Reverse transcriptase reagents and steps to the new method using Induro® Reverse Transcriptase (NEB, cat # M0681).
- Updated the RNase Inhibitor reagents and steps to the new method using Murine RNase Inhibitor (NEB, M0314).
- Updated first Agencourt RNAClean XP bead clean in Library Preparation section to elute into 23 ul Nuclease-free water, retain the full 23 ul and no longer have to add 3 ul of water in the next step.
- Updated "Flow cell reuse and returns" section to specify compatibility and use-cases for the Flow Cell Wash Kit with the RNA sequencing kit and RNA flow cells.