Human cell line RNA

Introduction

This protocol describes a method to extract total RNA from human cell lines (GM12878). The recommended method is based on work previously described by Workman et al, 2018.

Materials

  • 5 x 10^7 cells
  • Refrigerated centrifuge (with capacity for 50 ml Falcon tubes)
  • Vortex mixer
  • 1.5 ml Eppendorf tubes
  • 50 ml Falcon tubes
  • 1x phosphate buffered saline (PBS)
  • TRIzol
  • Chloroform
  • Isopropanol
  • Ethanol
  • TE buffer (1 mM EDTA, pH 8.0)

Method

  1. Harvest and pellet 5 x 10^7 cells in a 50 ml Falcon tube. If any liquid remains associated with the pellet, spin down the tube and aspirate the remaining supernatant.
  2. Add 500 µl of 1x PBS to pelleted cells.
  3. Centrifuge for 3 minutes at 300 x g and discard the supernatant.
  4. Add 4 ml of TRIzol to the cell pellet and vortex to homogenise.
  5. Incubate for 5 minutes at room temperature.
  6. Add 800 µl of chloroform and vortex.
  7. Incubate for 5 minutes at room temperature.
  8. Vortex and centrifuge for 15 minutes at 2000 x g at 4°C.
  9. Transfer the supernatant to a new 50 ml Falcon tube and add an equal volume of isopropanol.
  10. Invert the tube 15 times and incubate at room temperature for 15 minutes.
  11. Centrifuge for 20 minutes at 2000 x g at 4°C.
  12. Discard the supernatant.
  13. Add 4 ml of ice-cold 70% ethanol to wash the pellet.
  14. Centrifuge for 5 minutes at 2000 x g at 4°C.
  15. Discard the supernatant.
  16. Use a sterile paper wipe to absorb the ethanol from the tube walls.
  17. Allow the pellet to air-dry for 1 minute.
  18. Resuspend the pellet in 100 µl of TE by pipette mixing.
  19. Aliquot the sample as necessary and store aliquots at -80°C.

Results

  • Yield: 230 µg
  • OD 260/280: 1.89
  • OD 260/230: 0.81

Note: The lower than expected A260/230 ratio is indicative of TRIzol contamination. The performance of the PCR-cDNA Sequencing Kit is not adversely affected as long as the TRIzol concentration present in the reverse transcription and strand switching (first enzymatic step) is <0.5%.

Cell line RNA1

  • Agilent Bioanalyzer RNA 6000 Nano Kit, RIN: 9.7

Cell line RNA2

Sequencing performance

Libraries for nanopore sequencing were prepared from 50 ng of total RNA ±200 pg of ERCC RNA Spike-In Mix, using the PCR-cDNA Sequencing Kit.

  • Read length profile:

Cell line RNA3

Figure 1. The length distribution of reads that align to NA12878 and the ERCC panel. Panel A: the length distribution of reads that align to the NA12878 reference genome. Panel B: the proportion of the ERCC transcript covered by a read aligning to that transcript. The observed lengths of the reads that aligned to the ERCC panel show the majority of reads cover almost the entire transcript (as is expected, as the PCR-cDNA Sequencing Kit enriches for full-length RNA template molecules). This suggests that length distribution of reads in Panel A is representative of the length of the RNA molecules present in the sample and is not being biased during the library preparation process. The Spearman’s rank correlation coefficient (rho) and the coefficient of determination (r^2) for the ERCC alignments were ~0.95, further suggesting that there is very little bias in the library preparation and sequencing.

Change log

Version Change
v1, March 2019 Initial protocol publication

Last updated: 4/3/2024

Document options